Product: ISOMETER ISO EV 425  
 
  Bender GmbH
 
EV425
 

Isulation monitoring device with AGH420 coupling device

The main application fields are unearthed DC charging stations (mode 4 according to IEC 61851-23) for electric vehicles (IT systems) with nominal system voltages of DC 0…1000 V. Due to a separate supply voltage, de-energised systems can also be monitored.

The currently measured insulation resistance is indicated on the LC display. If the reading is below the selected response value, the response delay "ton" begins. Once the response delay "ton" has elapsed, the alarm relays "K1/K2" switch and the alarm LEDs "AL1/AL2" light up. The point of fault L+, L- or the symmetrical insulation resistance is indicated on the display.

Device features

  • Monitoring for DC charging stations (mode 4 according to IEC 61851-23)
  • Mains voltage measurement (r.m.s.) with under-/overvoltage detection
  • DC voltage measurement to earth (L+/PE and L-/PE)
  • Automatic adaptation to the system leakage capatiance up to 5 µF
  • Automatic device self-test with connection monitoring
  • Selectable start-up delayx, response delay and delay on release
  • Two separetely adjustable response value ranges of 1…500kΩ (Alarm 1, Alarm 2)
  • Alarm siglalling via LEDs (AL1, AL2), a display and alarm relays (K1, K2)
  • N/C operation or N/O operation selectable
  • Measured value indication via multifunctional LCD
  • Fault memory can be activated
  • RS-485 (galvanically isolated) including the following protocols:
    BMS interface (Bender measuring device interface) for data exchange with other Bender components
    Modbus RTU
    IsoData (for continuous data output)

Password protection to prevent unauthorised parameter changes

  